RE-Y(St)Y-fl - Unka Kablo

EN 50288-7

RE-Y(St)Y-fl

These cables are designed for the transmission of analogue or digital signals in indoor or outdoor connection tools and control systems. They are mainly used in communication, telecom and automation systems, petrochemical plants, oil & gas and construction industries.

ConductorStranded electrolytic copper wire Class 2 (BS EN 60228:2005)
InsulationPVC (Polyvinyl Chloride) Compound (EN 50290-21)
Colour CodeBlack/White, each pair numbered
WrappingPES Tape
Overall ScreenTinned Copper Drain Wire (0,5 mm2) + AL-PES Tape
SheathPVC (Polyvinyl Chloride) Compound (EN 50290-22)
Sheath ColourRAL 9005 Black ; RAL 5015 Blue ; RAL 7001 Grey
Temperature Range-30°C to +70°C (Fixed Installation)
Minimum Bending Radius7,5 x outer diameter
Flame RetardantTest on single cable : IEC 60332-1-2 Test on bunched cable: IEC 60332-3-24 (Cat. C)
Conductor cross-sectionnom.mm20,50,7511,31,5
Conductor resistancemax.Ω/km36,72518,514,212,3
Insulation resistancemin.MΩxkm100
Mutual capacitancemax.nF/km120120120130130
L/R ratiomax.µH/Ω2540
Test voltage Urms (core:core)V2000
Test voltage Urms (core:screen)V2000
Operating VoltageV300
300 V
CROSS SECTIONOUTER DIA.±(%5)G
mm2mmKg/Km
1x2x0,55,2037,27
2x2x0,57,6064,24
4x2x0,58,90100,38
5x2x0,59,80118,43
6x2x0,510,60135,91
8x2x0,512,60178,48
10x2x0,513,80217,68
12x2x0,514,20247,22
16x2x0,515,70309,45
20x2x0,517,70383,16
24x2x0,519,70458,54
30x2x0,520,90546,81
1x2x0,755,8047,19
2x2x0,758,4081,85
4x2x0,759,70125,38
5x2x0,7510,70149,12
6x2x0,7511,70177,73
8x2x0,7514,00234,05
10x2x0,7515,10277,59
12x2x0,7515,60318,48
16x2x0,7517,40410,97
20x2x0,7519,60508,86
24x2x0,7521,90609,30
30x2x0,7523,20729,46
1x2x16,2054,08
2x2x19,1095,49
4x2x110,50149,28
5x2x111,80184,49
6x2x112,70212,97
8x2x115,20280,84
10x2x116,60343,29
12x2x117,10392,79
16x2x119,20508,15
20x2x121,40616,91
24x2x123,90738,76
30x2x125,50901,15
1x2x1,36,8065,06
2x2x1,310,10116,95
4x2x1,311,90193,80
5x2x1,313,10232,04
6x2x1,314,40277,07
8x2x1,317,20364,99
10x2x1,318,50436,06
12x2x1,319,40515,18
16x2x1,321,50655,61
20x2x1,324,20812,58
24x2x1,327,20986,35
30x2x1,328,801187,85
1x2x1,57,2071,42
2x2x1,510,70128,96
4x2x1,512,70215,99
5x2x1,514,20266,47
6x2x1,515,40309,65
8x2x1,518,40408,16
10x2x1,520,10499,67
12x2x1,520,70574,66
16x2x1,523,20745,08
20x2x1,526,10921,48
24x2x1,529,201102,63
30x2x1,531,101345,55
500 V
CROSS SECTIONOUTER DIA.±(%5)G
mm2mmKg/Km
1x2x0,56,2045,69
2x2x0,59,1078,95
4x2x0,510,50117,28
5x2x0,511,80144,51
8x2x0,514,50212,67
10x2x0,516,60263,92
12x2x0,517,10298,08
20x2x0,521,40460,07
30x2x0,525,50666,50
1x2x0,756,6053,05
2x2x0,759,7092,98
4x2x0,7511,50148,87
5x2x0,7512,70176,74
10x2x0,7517,90326,71
16x2x0,7520,70479,45
20x2x0,7523,30591,87
30x2x0,7527,80859,39
1x2x17,0060,13
2x2x110,40107,00
4x2x112,30174,03
5x2x113,80214,47
8x2x117,80325,37
10x2x119,40396,43
16x2x122,50584,20
20x2x125,30720,82
24x2x128,20861,04
30x2x130,101046,22
1x2x1,37,4069,55
2x2x1,311,30131,31
4x2x1,313,10208,53
5x2x1,314,60256,81
8x2x1,318,10386,91
10x2x1,320,70480,46
12x2x1,321,40552,18
16x2x1,324,00715,08
20x2x1,327,20897,46
24x2x1,330,401072,56
30x2x1,332,201289,09
1x2x1,57,5073,24
2x2x1,511,40138,28
4x2x1,513,30222,49
5x2x1,514,90274,70
10x2x1,521,00514,61
12x2x1,522,00604,44
20x2x1,527,60964,86
30x2x1,532,901405,99