RE-2X(ST)H - Unka Kablo

EN 50288-7

RE-2X(ST)H

These cables are designed for the transmission of analogue or digital signals in indoor or outdoor connection tools and control systems. They are mainly used in communication, telecom and automation systems, petrochemical plants, oil & gas and construction industries. In the event of a fire, thanks to their HFFR compound, they do not catch fire easily and the fire goes off itself. These cables have low smoke density and they do not produce poisonous and corrosive gases during fire.

ConductorStranded electrolytic copper wire Class 2 (BS EN 60228:2005)
InsulationXLPE (Cross-Link Polyethylene) Compound (EN 50290-2-29)
Colour CodeBlack/White, each pair numbered
WrappingPES Tape
Overall ScreenTinned Copper Drain Wire (0,5 mm2) + AL-PES Tape
SheathHFFR (Halogen Free) Compound (EN 50290-2-27)
Sheath ColourRAL 9005 Black ; RAL 5015 Blue ; RAL 7001 Grey
Temperature Range-30°C to +90°C (Fixed Installation)
Minimum Bending Radius7,5 x outer diameter
Flame PropagationIEC 60332-3-24
Smoke DensityIEC 61034-2
Test on Corrosiveness of Combustion GasesIEC 60754-2
Halogen Free TestIEC 60754-1
Conductor cross-sectionnom.mm20,50,7511,31,5
Conductor resistancemax.Ω/km36,72518,514,212,3
Insulation resistancemin.MΩxkm5000
Mutual capacitancemax.nF/km6565657575
L/R ratiomax.µH/Ω2540
Test voltage Urms (core:core)V2000
Test voltage Urms (core:screen)V2000
Operating VoltageV300
300 V
CROSS SECTIONOUTER DIA. ±(%5)G
mm2mmKg/Km
1x2x0,55,2036,82
2x2x0,57,6063,46
4x2x0,58,9099,36
5x2x0,59,80117,29
8x2x0,512,00173,24
10x2x0,513,80215,72
12x2x0,514,20245,85
20x2x0,517,70383,69
1x2x0,755,8046,62
2x2x0,758,4080,90
4x2x0,759,70124,26
5x2x0,7510,70147,86
10x2x0,7515,10275,43
16x2x0,7517,40406,47
20x2x0,7519,60502,76
1x2x16,2053,46
2x2x19,1094,44
4x2x110,50148,05
5x2x111,80182,96
10x2x116,60340,71
20x2x121,40613,28
1x2x1,36,8064,37
2x2x1,310,10115,77
4x2x1,311,90192,26
8x2x1,316,40359,17
12x2x1,319,40511,41
16x2x1,321,50656,23
24x2x1,327,20993,37
1x2x1,57,2070,69
2x2x1,510,70127,71
4x2x1,512,70214,34
5x2x1,514,20264,45
10x2x1,520,10499,80
20x2x1,526,10930,49
500 V
CROSS SECTIONOUTER DIA. ±(%5)G
mm2mmKg/Km
1x2x0,56,2045,85
2x2x0,59,1079,21
4x2x0,510,50117,59
5x2x0,511,80144,89
8x2x0,514,50213,18
10x2x0,516,60264,56
12x2x0,517,10300,46
20x2x0,521,40485,52
1x2x0,756,6053,22
2x2x0,759,7093,26
4x2x0,7511,50149,24
5x2x0,7512,70177,15
10x2x0,7517,90327,41
16x2x0,7520,70483,64
20x2x0,7523,30599,14
1x2x17,0060,31
2x2x110,40107,30
4x2x112,30174,43
5x2x113,80214,96
8x2x116,90319,75
10x2x119,40399,82
12x2x120,10457,23
20x2x125,30732,37
1x2x1,37,4069,74
2x2x1,311,30131,67
4x2x1,313,10208,96
6x2x1,315,90299,03
8x2x1,318,10387,62
10x2x1,320,70484,66
12x2x1,321,40553,09
16x2x1,324,00716,17
24x2x1,330,401074,23
1x2x1,57,5073,43
2x2x1,511,40138,65
4x2x1,513,30222,92
5x2x1,514,90275,23
10x2x1,521,00515,50
20x2x1,527,60991,79